- News
All the latest updates on building safety reformRegulations latest
- Focus
- Comment
- Programmes
- CPD
- Building the Future
- Jobs
- Data
- Subscribe
- Events
2024 events calendar
Explore nowBuilding Awards
Keep up to date
- Building Boardroom
All the latest updates on building safety reform
2024 events calendar
Explore nowBuilding Awards
Keep up to dateComparable efficiencies of low-energy and renewable technologies | |||
Renewable technology | Candidate buildings | Annual saving per £100,000 cost | |
kWh | kg CO2 | ||
Tower-mounted wind | Industrial, distribution | 90,000 | 39,000* |
Building-mounted | Most types of building | 36,000 | 15,500* |
Photovoltaic panels or roof | Most types of building | 11,500 | 4,800* |
Photovoltaic rain screen or glass | Prestige offices or retail | 8,000 | 3,450* |
Passive solar water heating | Residential, commercial, hotels and leisure | 45,000 | 8,500** |
Ground-source heat pump | Most types of building | 36,000 | 6,850** |
Borehole cooling | Offices, hotel, leisure | 11,000 | 4,650* |
Biomass boilers | Most types of building | 90,000 | 17,000** |
Biomass CHP | Industrial, hotel, | 26,000 | 10,800* |
leisure, hospital | 57,000 | 10,800** | |
* compared with electricity | |||
** compared with gas |
Indicative capital costs of ground source heat pumps and conventional heating and cooling plant | |||
Small (4 kWh) (£) | Medium (50 kWh) (£) | Large (400 kWh) (£) | |
Condensing boiler and flue | 1,200 | 4,200 | 17,000 |
Air-cooled chiller | 1,000 | 6,000 | 50,000 |
Heat pump | 3,500-4,500 | 30,000-40,000 | 140,000-170,000 |
Horizontal “Slinky” collector | 3,000-4,000 | 40,000-50,000 | 360,000-390,000 |
Vertical borehole collector | 2,000-3,000 | 50,000-70,000 | 360,000-390,000 |
Costs exclude distribution pipework from the collection network to the heat pump and plant room | |||
installations. Main contractors’ preliminaries, overheads and profit are also excluded. |