Keep up to dateKey specification data and design features | |
Roof U-value | 0.23 W/m2.K |
Wall U-value | 0.25 W/m2.K |
Ground U-value | 0.27 W/m2.K |
Window U-value | 0.18 W/m2.K (Double glazing with mid-pane venetian blinds) |
Structural frame | Concrete |
Floor construction | In-situ concrete floors with exposed soffits |
Ventilation strategy | Natural ventilation for open-plan floor areas (75%) and local air handling units for %09meeting rooms (25%) |
Heat source | Gas-fired condensing boilers%3Cbr /%3E |
Photovoltaic array | 25 kW (peak-rated output), 200m2 total array area |
Solar water heating installation | Sized to pre-heat at installation least 40% of annual domestic hot water%3Cbr /%3E |
General lighting installation | 300 lux using T5 fluorescent installation luminaires (installed load 8-10W/m2) |
Rainwater recovery | Rainwater storage tank to collect surface water from the roof and recycle for WC flushing%3Cbr /%3E |
BREEAM rating | Excellent |