Keep up to dateArea weighted average U-value standards (W/m²K) | |
Element | Area weighted average (W/m²K)* |
Wall | 0.35 |
Floor | 0.25 |
Roof | 0.25 |
Windows, rooflights and curtain walls | 2.20 |
Pedestrian doors | 2.20 |
Vehicle access doors | 1.50 |
Roof ventilators and smoke vents | 6.00 |
* Individual elements are subject to an overall limiting value over and above the area weighted average |
Comparative design standards for thermal performance | |||
Element | Unit | Typical standard | Passivhaus standard |
Heating demand | BTU/ft²/heating degree day | 5-15 | 1 |
Air leakage | Volume/hour | 1 | 0.6 |
Heating load | KWh/m²/annum | 150 | 15 |
Wall | (W/m²K) | 0.35 | 0.15 |
Window | (W/m²K) | 2.20 | 0.80 |
Extra-over costs for thermal performance enhancements to glazing | ||
Component | Unit | Extra-over cost |
Triple-glazed panel with krypton gas | m² | £75 |
Interpane gas to double-glazed unit (argon) | m² | Nil |
Interpane gas to double glazed unit (krypton) | m² | £15 |
Low-e glass coating | m² | Nil |
09 - Comparative capital cost and performance of thermal insulants | |||||||
Insulant | Class | Thickness (mm) | Location | Cost (£/m²) | Thermal conductivity W/mK | Properties | |
Thermal | Durability | ||||||
Rock wool | Mineral fibre | 100 | Pitched roof/wall | 4-6 | 0.033 - 0.044 | XX | XX |
170 | Pitched roof | 10-14 | 0.033 - 0.044 | XX | XX | ||
Glass wool | Mineral fibre | 100 | Pitched roof | 7-9 | 0.033 - 0.044 | XX | XX |
150 | Wall | 8-10 | 0.033 - 0.044 | XX | XX | ||
Rigid urethane foam (PUR) | Plastic cellular | Wall | 11-13 | 0.022 - 0.028 | XXX | XX | |
Polyisocyanurate | Plastic cellular | 100 | Pitched Roof | 8-10 | 0.029 - 0.031 | XXX | XXX |
60 (tapered) | Flat roof | 35-45 | 0.029 - 0.031 | XXX | XXX | ||
Expanded Polysterene (EPS) | Plastic cellular | 75 | Wall | 8-10 | 0.032 - 0.040 | XX | XXX |
100 | Pitched roof | 9-11 | 0.032 - 0.040 | XX | XXX | ||
Extruded polystyrene (XPS) | Plastic cellular | 135 | Flat roof | 25-32 | 0.028 - 0.036 | XXX | XXX |
50 | Below-ground walls | 23-26 | 0.028 - 0.036 | XXX | XXX | ||
Cellulose fibre | Plant/animal fibre | 100 | Wall | 9-11 | 0.036 - 0.040 | XX | X |
Wool | Plant/animal fibre | 100 | Wall | 13-15 | 0.037 - 0.040 | XX | XX |