Equipment | IR 120C |
Product group | Passive infrared |
Application | Intrusion detection |
Manufacturer | Alarmcom |
Address | Ibis House, Riverside Estate, London Colney, Herts. AL2 1HJ |
Telephone | 01727 738500 |
Fax | 01727 827260 |
Available from | Alarmcom, as above |
Trade price (ex VAT) | £14.95 |
CE Mark awarded | Yes |
Lens type | Black mirror with triplex optics |
Interchangeable lenses | Standard wide angle with look down zone or continuous curtain |
Range on | Wide angle 12m or |
centre axis | curtain 20m |
No of detection zones | 52 |
Coverage adjustment | Optional wall and ceiling adjustable mounting brackets |
Dual/quad element sensor | Dual |
Temperature compensation | Yes |
Alarm period | 2 – 3 sec |
Other signal processing options | Four application settings, 15 Kg pet immunity, or 40Kg with pet clip fitted |
Walk test facility | Yes |
Housing material | ABS Cycolac S701S to UL 94HB |
Self-testing functions | Yes |
Power supply voltage | 8 – 16v DC |
Max current consumption | 6mA |
IP rating | IP41 |
Size (mm) | 115H x 50W x 41D |
Warranty | 5 years |
Product assessment | |
Design and design features | **** |
Circuitry and components | **** |
Ease of installation and wiring | **** |
Range & variety of functions | *** |
Accompanying instructions | *** |
Technical advice and backup | *** |
Value for money | **** |
Key: Outstanding ***** Very good **** Above average *** Average ** Below average * |
Stability assessment | |
Tolerance to cold air turbulence | ***** |
Tolerance to hot air turbulence | ***** |
Tolerance to quartz halogen lamp | ***** |
Tolerance to fluorescent tube | ***** |
Tolerance to insect test | ***** |
Key: Detector operated correctly throughout test ***** |