Table 1: Work that need not be notified to building control bodies
Work consisting of:
Replacing accessories such as socket-outlets, control switches and ceiling roses
Replacing the cable for a single circuit only, where damaged, for example, by fire, rodent or impact (a)
Re-fixing or replacing the enclosures of existing installation components (b)
Providing mechanical protection to existing fixed installations (c)
Work that is not in a kitchen or special location and does not involve a special installation (d) and consists of:
Adding lighting points (light fittings and switches) to an existing circuit (e)
Adding socket-outlets and fused spurs to an existing ring or radial circuit (e)
Installing or upgrading main or supplementary equipotential bonding (f)
Notes
(a) On condition that the replacement cable has the same current carrying capacity, follows the same route and does not serve more than one sub-circuit through a distribution board
(b) If the circuit’s protective measures are unaffected
(c) If the circuit’s protective measures and current-carrying capacity of conductors are unaffected by increased thermal insulation
(d) Special locations and installations are listed in Table 2
(e) Only if the existing circuit protective device is suitable and provides protection for the modified circuit, and other safety provisions are satisfactory
(f) Such work shall comply with other applicable legislation, such as the Gas Safety (Installation and Use) Regulations
Table 2: Special locations and installations (a)
Locations containing a bath tub or shower basin
Swimming pools or paddling pools
Hot air saunas
Electric floor or ceiling heating systems
Garden lighting or power installations
Solar photovoltaic (PV) power supply systems
Small-scale generators such as micro-CHP units
Extra-low voltage lighting installations, other than pre-assembled, CE-marked lighting sets
Notes
See IEE Guidance Note 7 which gives more guidance on achieving safe installations where risks to people are greater